CA2.jpg (9777 bytes)


ROOFTOPS, HEADLINERS, BACKWALL, A/C & HEATER UNITS

R-6100 ROOFTOP



Heavy, Medium & 

Light Duty Trucks
Construction
Agricultural Cabs
R-6100 SPECIFICATIONS
BTU's:  Cooling 16,000 BTU/Hr with 36 (4.7 kW with 2.2C) ref. temp. and 80F (26.7C)
               wet bulb entering air
Air Flow:  265 CFM (450 m3/h)
Weight:  44 lbs. (20 kg)
Condenser Coil:  The coil is aluminum fin and copper tube construction.  This material
                                selection, which includes a tube or 0.22: (6 cm) wall thickness, results in
                                an effective, light weight, and rugged coil.
Condenser Motor/Fan:  The motor is a permanent magnet type selected for its extended
                                            life.  The motor is sealed and a slinger ring and hub cap added for
                                           weather protection.  The fan is aluminum with a heavy duty spider
                                           and riveted blades.
Models:  R-6100-0 (12 VDC), R-6100-0-24 (24 VDC)

R-9727 ROOFTOP



Construction
Agricultural
Mining

R-9727 SPECIFICATIONS
BTU's:  Cooling 22,000 BTU/Hr with 36 (6.4 kW with 2.2C) ref. temp. and 80F (26.7C)
               wet bulb entering air
Air Flow:  Evaporator - 320 CFM (544 m3/h)
                   Condenser - 850 CFM (1444 m3/h)
Weight:  104 lbs. (47 kg)
Motors:    Evaporator - One, 12 VDC, three-speed, 24 VDC 
                   Condenser - One, 12 VDC, single-speed, 24 
                   VDC
Current Draw:  29 amps @ 13.6 VDC (inc. 4 amps for A/C 
                      clutch)
                              15 amps @ 27.2 VDC (includes 2 amps for
                              A/C clutch)
Controls:  Three speed blower and adjustable thermostat
Models:  R-9727-1 (12 VDC), R-9727-1-24 (24 VDC)

R-9757 ROOFTOP
Heater/Air Conditioner Unit



Construction
Agricultural
Mining

R-9757 SPECIFICATIONS
BTU's:  Heating - 45,000 BTU/Hr @ 100F (13.2 KW @ 37.8C) air. temp. rise
               Cooling - 25,000 BTU/Hr with 36F (7.3 KW with 2.2C) refrigerant temp. and 80F
               (26.7C) wet bulb entering air
Air Flow:  400 CFM (680 m3/h)
Weight:  135 lbs. (61kg)
Motors:  Evaporator - One 12 VDC, three speed (24 VDC available)
                 Condenser - One 12 VDC low profile (24 VDC available)
Current Draw:  38.2 amps @ 13.6 VDC, (includes 4 amps for A/C clutch)
                             19.1 amps @ 27.2 VDC (includes 2 amps for A/C clutch)
  Models:  R-9757-0 (12 VDC)
                R-9757-0-24 (24 VDC)

R-9777 Rooftop
Heater/Air Conditioner Unit

Construction
Mining
Agriculture

R-9777 SPECIFICATIONS
BTU's:  Heating - 45,000 BTU/Hr @ 100F (13.2 KW @ 37.8C) air
               temp. rise 
               Cooling - 25,000 BTU/Hr with 36F (7.3 KW with 2.2C)
               refrigerant temp. and 80F (26.7C) wet bulb entering air
Air Flow:  400 CFM (680 m3/h)
Weight:  65 lbs.
Motors:  Evaporator - One 12 VDC, three speed (24 VDC available)
                Condenser- One 12 VDC low profile (24 VDC available)
Models:  R-9777-0          Heater A/C 12 VDC
                R-977-0-24       Heater A/C 24 VDC
                R-9777-1           A/C Only 12 VDC
                R-9777-1-24     A/C Only 24 VDC
Currents Draw:  38.2 amps @ 13.6 VDC (includes 4 amps for A/C
                               clutch)
                               19.1 amps @ 27.2 VDC (includes 2 amps for A/C
                               clutch)


R-2000 HEADLINER
Air Conditioner Unit



Trucks
Motor Homes
Vans
Refuse

R-2000 SPECIFICATIONS
BTU's:  Cooling - 17,000 BTU/Hr w/36 F (5 kW w/s.sC) refrigerant temp. and 80 (26.7C) wet
               bulb entering air
ir Flow:  235 CFM (400 m3/h)
Weight:  24 lbs. (11 kg)
Current Draw:  18.5 amps @ 13.6 VDC (includes 4 amps for A/C clutch)
                             9.3 amps @ 27.2 VDC (includes 2 amps for A/C clutch)
Controls:  Three speed fan, adjustable thermostat
Models:  R-2000-6 (12 VDC), R-2000-6-24 (24 VDC)

R-9715 HEADLINER
High Capacity ceiling Mount Air Conditioner 

Buses
Vans
Fire Trucks

R-9750 HEADLINER
Air Conditioner Unit with Heat Option

Construction
Mining
Agriculture

BTU's:  Cooling-17,000 BTU/Hr with 36 (5 kW with 2.2C) 
               refrigerant temp, and 80F (26.7C) wet bulb entering
               Heating-25,600 BTU/Hr @ 100F (7.5 kW @ 37.8C)
               oil temp. rise
Air Flow:  240 CFM (408 m3/h)
R-9715 SPECIFICATIONS Weight:  44 lbs (20 kg)
BTU's:  Cooling-39,500 BTU/Hr with 36 (11.6 kW with 2.2C) 
               refrigerant temp, and 80F (26.7C) wet bulb entering air
Air Flow:  577 CFM (980 m3/h) Current Draw:  13 amps @ 13.6 VDC (includes 4 amps for A/C
                             clutch)
                             6.5 amps @ 27.2 VDC (includes 2 amps for A/C
                             clutch) 
Weight:  40 lbs. (18 Kg)
Current Draw:  26.3 amps @ 13.6 VDC (includes 4 amps for A/C
                             clutch)
                             13.2 amps @ 27.2 VDC (includes 2 amps for A/C
                             clutch)
Models:  Heater-A/C Units:  R-9750-5 (12 VDC), R-9750-5-24 (24 VDC)
                A/C Only Units:  R-9750-6 (12 VDC), R-9750-6-24 (24 VDC)
Models:  R-9715-0 (12 VDC), R-9715-0-24 (24 VDC)

Cab Air Conditioning:  800-880-7983

R-9755 HEADLINER
Air Conditioner Unit



Construction
Industrial
Mining

R-9755 SPECIFICATIONS
BTU's:  Cooling-17,000 BTU/Hr with 36 (5 kW with 2.2C) 
               refrigerant temp, and 80F (26.7C) wet bulb entering
Air Flow:  240 CFM (408 m3/h)
Weight:  32 lbs. (14.5 kg)
Current Draw:  14.1 amps @ 13.6 VDC (includes 4 amps for A/C
                             clutch)
                             7 amps @ 27.2 VDC (includes 2 amps for A/C
                             clutch) 
Models:  A/C Only Units:  R-9755-0 (12 VDC), R-9755-0-24 (24 VDC)

R-5045 BACKWALL
Heater/Air Conditioner Unit



Armored Cars
Aid Cars
Personnel Carriers

R-5045 SPECIFICATIONS
BTU's:  Heating-46,000 BTU/hr @ 150F (13.5 kW @ 66C) water to air differential
               Cooling-33,000 BTU/Hr with 36F  (9.7 kW with 2.2C) refrigerant temp, and 80F (26.7C) wet
               bulb entering air
Air Flow:  430 CFM (730 m3/h)
Weight:  47 lbs. (21 kg)
Current Draw:  22.5 amps @ 13.6 VDC (includes 4 amps for A/C
                             clutch)
                             11.2 amps @ 27.2 VDC (includes 2 amps for A/C
                             clutch) 
Models:  Rear Exhaust:  R-5045-2 (12 VDC) R-5045-2-24 (24 VDC)
                Fresh Air Intake:  R-5045-3 (12 VDC) R-5045-3-24 (24 VDC)

R-5075 BACKWALL SPECIFICATIONS
Heater/Air Conditioner Unit
Construction
Mining
Agriculture
R-7830 BACKWALL SPECIFICATIONS
Air Conditioner Unit
Fleets  Heavy & Medium Duty Trucks
Construction  Industrial
Agriculture
BTU's:  Heating-46,000 BTU/Hr @ 150F (13.5 kW @ 66C)
               water to air differential
               Cooling-33,000 BTU/Hr with 36F (9.5 kW w/2.2C)
               refrig. temp. and 80F (26.7C) wet bulb entering air
BTU's:  Cooling-17,180 BTU/Hr with 36F (5 kW w/2.2C) refrig.
               temp. and 80F (26.7C) wet bulb entering air
Air Flow:  430 CFM (730 m3/h) Air Flow:  260 CFM (442 m3/h)
Weight:  47 lbs. (21 kg) Weight:  25 lbs. (11 kg)
Motor:  One three-speed Controls:  High-low motor speed, four adjustable louvers,
                   adjustable thermostat
Current Draw:  21.8 amps @ 13.6 VDC (includes 4 amps for A/C
                             clutch)
                             10.9 amps @ 27.2 VDC (includes 2 amps for A/C
                             clutch) 
Current Draw:  18 amps @ 13.6 VDC (includes 4 amps for A/C
                             clutch)
                             9 amps @ 27.2 VDC (includes 2 amps for A/C
                             clutch) 
Models:  R-5075-0 (12 VDC) R-5075-0-24 (24 VDC) Models:  R-7830-0 (12 VDC) R-7830-0-24 (24 VDC)

R-8500 BACKWALL SPECIFICATIONS
Air Conditioner Unit/Heat Option
Construction
Mining
Agriculture
R-8545 BACKWALL SPECIFICATIONS
Heavy Duty Air Conditioner Unit/Heat Option
Mining
Construction  
Agriculture
BTU's:  Heating-22,000 BTU/Hr @ 100F (6.4 kW @ 37.8C)
               air temperature rise
               Cooling-15,200 BTU/Hr with 36F (4.5 kW w/2.2C)
               refrig. temp. and 80F (26.7C) wet bulb entering air
BTU's:  Heating-28,600 BTU/Hr @ 100F (8.4 kW @ 37.8C)
               air temperature rise
               Cooling-18,000 BTU/Hr with 36F (5.3 kW w/2.2C)
               refrig. temp. and 80F (26.7C) wet bulb entering air
Air Flow:  205 CFM (348 m3/h) Air Flow:  265 CFM (450 m3/h)
Weight:  24 lbs. (11 kg) Weight:  Heater & A/C - 39 lbs (18 kg)
                 A/C Only - 35 lbs (15 kg)
Motor:  Three-speed field wound Motor:  Totally sealed, 12 or 24 VDC permanent magnet type
               with long life brushes, and heavy duty pre-lubricated
               seated bail bearings
Current Draw:  13.5 amps @ 13.6 VDC (includes 4 amps for A/C
                             clutch)
                             6.75 amps @ 27.2 VDC (includes 2 amps for A/C
                             clutch) 
Current Draw:  16.1 amps @ 13.6 VDC (includes 4 amps for A/C
                             clutch)
                             8 amps @ 27.2 VDC (includes 2 amps for A/C
                             clutch) 
Controls:  Mode selector toggle switch (heat or A/C), three
                   speed fan switch, fixed setting A/C thermostat cable
                   controlled water valve
Models:  R-8500-0 (12 VDC) Heater/Air Conditioner
                R-8500-0-24 (24 VDC) Heater/Air Conditioner
                R-8500-1 (12 VDC) A/C Only
                R-8500-1-24 (24 VDC) A/C Only
Models:  R-8545-0 (12 VDC) Heater/Air Conditioner
                R-8545-0-24 (24 VDC) Heater/Air Conditioner
                R-8545-1 (12 VDC) A/C Only
                R-8545-1-24 (24 VDC) A/C Only

R-5040 BACKWALL
Heater Unit with A/C Option



Motor HomesArmored Cars
Aid Cars
Large Cabs

R-5040 SPECIFICATIONS
BTU's:  Heating-48,000 BTU/hr @ 100F (14kW @ 37C) air temp. rise
               Cooling 32,000 BTU/Hr with 36F (9.4 kW with 2.2C) ref. temp. and 80F (26.7C) 
Air Flow:  425 CFM (722 m3/h)
Weight:  Heater - 30 lbs. (14 kg)
                 Heater-A/C - 39 lbs. (18 kg)
Motor:  Two three speed
Current Draw:  27 amps @ 13.6 VDC (includes 4 amps for A/C clutch); 14.5 amps @ 27.2 VDC 
                             (including 2 amps for A/C clutch)
Models:  R-5040-0 (12 VDC) Heater
                 R-5040-2 (24 VDC) Heater
                 R-5040-4 (12 VDC) Heater/Air Conditioner
                 R-5040-6 (24 VDC) Heater/Air Conditioner